Programmable Logic Controller MCQ Quiz Test No.: 8 0 votes, 0 avg 20 Created by Prof. Dhruv Patel MCQ Quiz – Test: 8 : Programmable Logic Controller This quiz helps students to increase their Programmable Logic Controller knowledge. 1 / 10 Which one of the following timer parameter represents the resolution of the timer ? ACCUMULATED TIME PRESET TIME BASE TIME None of these 2 / 10 Which one of the following timer parameter determines the time duration for the timing circuit? ACCUMULATED TIME PRESET TIME BASE TIME None of these 3 / 10 Which one of the following timer parameter represents the value that increments as the timer is timing? ACCUMULATED TIME PRESET TIME BASE TIME None of these 4 / 10 _____________loss the accumulated time every time the rung condition becomes false. TON Timer RTON Timer TOFF Timer None of these 5 / 10 _____________ must be used to zero the accumulated value in an RTON timer. ACC PRESET RESET None of these 6 / 10 The figure shown below represent ____________ When the relay coil is energized, there is a time delay in closing. When the relay coil is de-energized, there is a time delay before the contact opens. When the relay coil is energized, there is a time delay in opening. When the relay coil is de-energized, there is a time delay before the contact closes. 7 / 10 The figure shown below represent ____________. When the relay coil is energized, there is a time delay in closing. When the relay coil is de-energized, there is a time delay before the contact opens. When the relay coil is energized, there is a time delay in opening. When the relay coil is de-energized, there is a time delay before the contact closes. 8 / 10 The figure shown below represent ____________ When the relay coil is energized, there is a time delay before contact closes. When the relay coil is de-energized, there is a time delay before the contact opens. When the relay coil is energized, there is a time delay before contact opens. When the relay coil is de-energized, there is a time delay before the contact closes. 9 / 10 Certain contacts of a mechanical timing relay are designed to operate at a preset time interval: Certain contacts of a mechanical timing relay are designed to operate at a preset time interval: after the coil is energized. either a or b after power is applied to the circuit 10 / 10 The figure shown below represent ____________ When the relay coil is energized, there is a time delay before contact closes. When the relay coil is de-energized, there is a time delay before the contact opens. When the relay coil is energized, there is a time delay before contact opens. When the relay coil is de-energized, there is a time delay before the contact closes. Your score isThe average score is 34% LinkedIn Facebook Twitter VKontakte 0% Restart quiz Test No. 1 Test No. 2 Test No. 3 Test No. 4 Test No. 5 Test No. 6 Test No. 7 Test No. 8 Test No. 9 Test No. 10 Test No. 11